Chinese Medical Equipment Journal ; (6): 70-72,97, 2015.
Article in Chinese | WPRIM | ID: wpr-600531

ABSTRACT

Objective To explore the advantages of Argus method by comparing the accuracy and timeliness of Argus and artificial methods for measuring femoral head necrosis area in MRI scanning.Methods Totally 17 patients (31 hips) were measured with Argus and artificial methods respectively for the necrosis area, and then the measuring results and time were compared, and the correlation was investigated between the results and the patients' pain degree, along with that between the results and the extent of femoral head collapse.Results The necrosis area ratios determined by Argus and artificial methods were (33.5±4.08)%and (34.6±4.06)%respectively, with no statistical difference between the ratios (P>0.05). The time consumed by artificial method was (21.3 ±3.62)min, significantly longer than (7.89 ±1.03)min by Argus method, with P<0.001. Regression analysis proved that the necrosis areas were positively correlated with the patients' pain degree, and the correlation coefficient by Argus method was 0.807 8, more than 0.740 9 by artificial method. The femoral heads of 11 cases(16 hips) collapsed in the follow-up period, the necrosis areas were positively correlated with the patients collapse level, but the correlation coefficient by Argus method was 0.783 8, more than 0.726 7 by artificial method.Conclusion Argus method gains high accuracy and timeliness when used in MRI scanning of femoral head necrosis area, and thus is worth popularizing clinically.